Copper or CCA Ethernet Cable: What Buyers Need to Know

Copper-clad aluminium (CCA) and bare copper Ethernet cables can look similar, but their electrical properties differ. Learn how conductor material affects resistance, PoE voltage drop, cable temperature and project compliance, plus what distributors and contractors should verify before specifying or purchasing bulk network cable.

By WEIHUI CablesUpdated
  • Buying Guides
Copper or CCA Ethernet Cable: What Buyers Need to Know

Two Cat6 cables can look similar on a quotation and even show the same basic wire-map result, yet use very different conductor materials. That difference matters when a project depends on PoE devices, long cable runs or a structured cabling warranty.

Copper-clad aluminium (CCA) can reduce material cost, but it does not have the same electrical properties as bare copper. For distributors, contractors and system integrators, the real question is not simply which cable is cheaper. It is whether the conductor, cable construction and test evidence meet the requirements of the installation.

Copper vs. CCA: A Quick Project Guide
Scenario What to verify
PoE cameras and access points Conductor resistance against the PoE class, the load at each port, and the temperature rise in the installed bundle
Long fixed runs Conductor material, gauge, cable length and voltage-drop budget evaluated together
Commercial structured cabling Component compliance, channel certification requirements and warranty conditions
Short or non-PoE links The actual application and the applicable requirements, rather than an assumption that lower cost is acceptable

The table is a preliminary procurement guide. It does not declare that CCA complies with any structured cabling standard; that has to be established for the specific product and the specific project.

Bare copper, aluminium and CCA are three different materials

For structured cabling, conductor material is only one part of compliance. The finished cable must meet the applicable cabling standard, and a conductor specification alone does not establish that the complete cable is compliant.

Bare copper is the reference point. Annealed copper sits at roughly 100% IACS, with a resistivity of 0.017241 Ω·mm²/m at 20 °C. It is ductile, terminates predictably, and behaves the same way at DC and at 250 MHz.

Aluminium is about 61% IACS at 0.028264 Ω·mm²/m, lighter and cheaper, and common in utility distribution and some coaxial constructions. In horizontal LAN cable it is rare, partly because bare aluminium oxidises quickly and does not take a crimp or punch-down the way copper does.

Copper-clad aluminium is neither of those. It is an aluminium core with a copper layer metallurgically bonded to it, not a coating or a plating. ASTM B566 grades the material by copper volume fraction — 10A at 10%, 15A at 15% — and sets a maximum resistivity for each grade. That is a conductor specification: it describes the wire, not what a finished cable made from that wire will do.

Conductor materials at 20 °C
Material Resistivity (Ω·mm²/m) Conductivity Resistance vs copper, same gauge
Bare copper 0.017241 ~100% IACS 1.00×
CCA, 10% copper (ASTM B566 10A) 0.027430 max ~63% IACS 1.59×
CCA, 15% copper (ASTM B566 15A) 0.026765 max ~64% IACS 1.55×
Bare aluminium 0.028264 ~61% IACS 1.64×

The last column is the one worth pausing on. Electrically, CCA sits much closer to aluminium than to copper. Treating it as copper with a thin coat overstates it; treating it as bare aluminium understates it, because the cladding is continuous copper and the termination and corrosion behaviour follow the copper surface.

Four different things get collapsed into the word compliant. A conductor specification such as ASTM B566 describes the wire. A finished-cable performance standard — ANSI/TIA-568.2-D, or the ISO/IEC 11801 series with cable requirements drawn from the IEC 61156 series — describes what the completed cable has to measure. A channel requirement describes what the installed link, including jacks, patch panels and patch cords, has to achieve on site. A safety listing such as UL 444 covers fire and electrical safety rather than transmission. Meeting one of these says nothing about the other three, and a CCA product has to be assessed separately against each.

What resistance does to a link

DC resistance follows from the metal and the cross-section. At 23 AWG the conductor area is about 0.258 mm²; at 24 AWG it is about 0.205 mm². Change either factor and the number moves, which is why gauge and material have to be read together.

DC resistance per 100 m at 20 °C
Conductor Per conductor One pair, loop
23 AWG copper 6.7 Ω 13.4 Ω
23 AWG CCA (10%) 10.6 Ω 21.3 Ω
23 AWG aluminium 11.0 Ω 21.9 Ω
24 AWG copper 8.4 Ω 16.8 Ω
24 AWG CCA (10%) 13.4 Ω 26.8 Ω

At 100 MHz the current in a copper conductor concentrates in a skin roughly 6.6 µm deep, and about 4.2 µm at 250 MHz. On a 23 AWG CCA conductor with 10% copper by volume, the cladding works out at roughly 15 µm, which is thicker than either figure. It is tempting to conclude from that geometry that high-frequency behaviour must therefore be close to copper. That conclusion does not follow.

At Ethernet frequencies, skin effect changes how current is distributed across the conductor, so the relationship between DC resistance and high-frequency insertion loss is not a simple one-to-one ratio. However, skin depth alone cannot establish whether a CCA cable meets a category’s transmission limits. That must be demonstrated by testing the finished cable against the applicable requirements.

The PoE figures below are a simplified calculation with stated assumptions: 100 m of cable, 20 °C, a two-pair PoE circuit at 600 mA (802.3at Type 2), conductor resistance only, and no allowance for connectors or patch cords. In that circuit the current leaves on one pair and returns on the other, with both conductors of each pair in parallel, so the path resistance is close to the per-conductor value.

At 600 mA the path drops about 4.0 V in 23 AWG copper, 6.4 V in 23 AWG CCA and 8.0 V in 24 AWG CCA over 100 m. The power lost in the conductor is roughly 2.4 W, 3.8 W and 4.8 W. These are theoretical figures for one configuration, not a prediction for a given installation: the result also depends on the actual load, the device’s minimum input voltage, cable temperature, connector resistance, bundle size and how the cable is installed.

So the conclusion is narrower than a verdict on CCA. PoE cable selection should consider actual load requirements, conductor resistance, cable length and thermal conditions rather than relying on category labels or price per metre alone.

The conductor is only one part of the channel. Pair geometry sets crosstalk, insulation sets capacitance, the jacket and shield set how the cable survives its environment, and the connector and termination decide whether the link holds its margin after the first re-plug. A copper cable with poor terminations fails the same test as a CCA cable with good ones.

Where it shows up in a project

Four situations come up often enough to be worth separating, because each stresses a different part of the design.

PoE cameras and access points sit at the end of a long horizontal run and draw continuous current. The questions are voltage drop, current per pair set, temperature rise and how many loaded cables share a bundle. A link that leaves the switch at 54 V can arrive with only a few volts of headroom above the device’s minimum, and that margin shrinks in a warm ceiling void or a packed tray.

Commercial structured cabling adds a contractual layer. Channel warranties are conditioned on compliant components end to end, so the relevant question is whether the specific cable, jacks and patch cords are covered by the warranty — not whether the cable passes a quick test on a bench.

Long fixed runs accumulate voltage drop and are expensive to replace. In risers, buried ducts and finished ceilings the cable that goes in is the cable that stays, which is why the decision is worth making against the longest run rather than the average one.

Installations expected to last through several fit-outs add termination and environment to the list. Repeated re-termination, moisture at outdoor entries and humid plant rooms all put stress on the connection, and how a conductor behaves there depends on termination practice, cladding integrity and the protection the installation provides rather than on the material alone.

The risks vary by application, but a shorter run or a non-PoE link does not automatically make a CCA cable compliant. Before considering any lower-cost alternative, verify the applicable cabling requirements, the finished cable’s tested performance and the project’s acceptance criteria.

Verifying what is actually inside the cable

Conductor material is rarely printed on the jacket. Cable legends normally give category, gauge, pair count and listing marks, and the metal is left to the datasheet. Verification therefore works from documents outward.

Supplier declarations and datasheets should state the conductor material, the grade if the conductor is CCA, the standard the finished cable was qualified to, and any third-party listing. A listing claim is only useful if the number can be checked against the listing body’s database and if the listing covers the specific product rather than a similar one.

Cross-section inspection under low magnification shows the copper layer against a silver-white core, and the boundary is visible on a cut end. Weight per unit length is a useful cross-check, because CCA is roughly a third the density of copper. Both are screening methods: they can raise a question, not settle one.

X-ray fluorescence gives a definitive read on composition when a dispute is worth settling properly. It establishes what the metal is, and nothing about transmission performance.

A four-wire resistance measurement avoids lead and contact resistance, but the reading still depends on conductor temperature, exact gauge, stranding and the length actually measured. Copper moves about 0.39% per °C, so a reel measured cold in a warehouse and a sample measured warm on site will not agree. A resistance measurement can show that a sample sits far outside the range expected for its gauge; it cannot identify the material on its own.

A basic wire-map test, a conductor resistance measurement and a standards-based cable certification test answer different questions. One should not be used as a substitute for another.

For a project quotation, start with the target cable category, maximum run length, PoE requirements, installation environment and estimated order quantity. These details help establish the appropriate conductor, gauge and cable construction for the application.

WEIHUI CABLES can review your project requirements and discuss suitable bulk network cable options. Share your target specifications and estimated quantity to start the discussion.